US S&A CW-5200DH Industrial Water Chiller 110V 60Hz for 8KW Spindle Laser Tube

US S&A CW-5200DH Industrial Water Chiller 110V 60Hz for 8KW Spindle Laser Tube
US S&A CW-5200DH Industrial Water Chiller 110V 60Hz for 8KW Spindle Laser Tube
US S&A CW-5200DH Industrial Water Chiller 110V 60Hz for 8KW Spindle Laser Tube
US S&A CW-5200DH Industrial Water Chiller 110V 60Hz for 8KW Spindle Laser Tube
US S&A CW-5200DH Industrial Water Chiller 110V 60Hz for 8KW Spindle Laser Tube
US S&A CW-5200DH Industrial Water Chiller 110V 60Hz for 8KW Spindle Laser Tube
US S&A CW-5200DH Industrial Water Chiller 110V 60Hz for 8KW Spindle Laser Tube
US S&A CW-5200DH Industrial Water Chiller 110V 60Hz for 8KW Spindle Laser Tube

US S&A CW-5200DH Industrial Water Chiller 110V 60Hz for 8KW Spindle Laser Tube

S&A CW-5200DH Industrial Water Chiller (AC 1P 110V 60Hz). Two 100W CO2 Glass Laser Tubes. 1400W cooling capacity, 50W DC pump, 1 outlet and 1 inlet.

The water temperature is able to be adjusted. Its mainly used to have the heat generated during the laser device working that gone through the refrigerating cycle in compressor refrigeration system and eventually transferred to the air. There are 2 specifications as 1 water outlet/inlet and dual water outlet/inlet, applicable to cool single laser glass tube. S&A industrial water chillers are popular for its 2 temperature control modes as constant temperature and intelligent temperature control.

Under intelligent mode, the water temperature is adjusted according to ambient temperature. With that 1 key solution, customers no longer need to worry about the water temperature adjustment of seasonal changes.

1400W cooling capacity; optional environmental refrigerant. Compact size, long working life and simple operation. ±0.3 precisely temperature control.

The intelligent temperature controller has 2 control modes, applicable to different applied occasions; with various setting and display functions. Multiple alarm functions: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm. Multiple power specifications; CE approval;RoHS approval.

Optional heater and water filter. R-22 / R-134a / R-410a. Over current protection for compressor, flow alarm, over temperature alarm. 22.8" x 11.4" x 18.5 (580 x 290 x 470mm). 27.6" x 16.9" x 22.8 (700 x 430 x 580mm).

When alarm occurs, the error code and the temperature will be alternately displayed. In alarming state, the alarm sound could be suspended by pressing any button, but the alarm display.

Remains until the alarm condition is eliminated. Alarm for over high water temperature. Alarm for over low water temperature.

Alarm for over high room temperature. The allowed highest water temperature.

The allowed lowest water temperature. Under normal circumstance, the new intelligent temperature controller does not need to adjust the controlling parameters.

It will self-adjust controlling parameters according to room temperature, guaranteeing to meet cooling requirements for machines. Flow alarm and output ports.

In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-5200series chillers possesses an unique low flow alarm protection. He cooling water circulation loop alarm causes and the work of the state table.

Blocked cooling water circulation loop. The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V. Cool for a Single 8KW Spindle or Welding Equipment or 2 x 100W. Adopt intelligent controller, it will automatically adjust control parameters according to room temperature changes. Cool for a Single 5KW Spindle or Welding Equipment Cooling. Cool for Single 0.8KW / 1.5KW Spindle. The water temperature is related to ambient temperature. One-stop automatic intelligent temperature control: in different environment, user does not need to change setting due to it will automatically switch to appropriate operating temperature. Applied to a cool a single 8KW CNC spindle, welding equipment or two 100W CO2 laser tubes.

Applied to cool a single 130W / 150W CO2 laser tube. Applied to a cool single 50W-75W laser diode, a single15W-30W solid-state laser or a single 30W RF laser tube. External Diameter: 10mm brass connector. Industrial cooling machines installation is very simple, the new machine for the first time using, you can install it as following steps. Open the package to check if the machine is intact and all the necessary accessories are completed.

Open the injection port to feed cooling water. Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling of carbon steel equipment, the water should be added an appropriate amount of anti - corrosion agentia.

Working in cold north area, its better to use noncorrosive antifreeze fluid. According to system conditions, please connect the water inlet and outlet pipe well. Plug in power, turn on the power switch.

Do not start up without water in the water tank! (1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal. (2) After the first boot, you must immediately check whether the water pipe leaks. (3) Power switched on, if the water temperature is below the set figure, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters. (4) As it takes a longer time to start the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently.

Check the water level in the water tank. The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep the water level in the green area, its allowed to add adequate water again. Please observe and record the current water level, and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage.

Adjust parameters of temperature controller. CW-5200 series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to Operating status and parameters adjustment. One of the differences between the CW5200 water tank and the CW3000 tank lies in that the CW5200 water tank can keep the water at a uniform temperature.

Its cooling function can keep the temperature at a certain value, which can be adjusted manually. The user may refer to the parameter instruction manual of the water tank for detailed description on the parameters. It is strongly suggested that the user should not change the parameters without authorization.

Our company accepts no responsibility for any insolvable problems caused by the users unauthorized changing of parameters. Cooling machine used in long term, you should open the machine and clean the dust in order to ensure good heat dissipation. You can use non corrosive antifreeze if you are in the northern cold regions. And electrical outlet are in good contact and the earth wire must be firmly grounded! Although the average operating current of the chiller is small, but the instantaneous operating current could be up to 6 10amps sometimes (The instantaneous operating current of models of AC110V power supply are possible to be up to 10 15amps).

Please make sure there is a stable and normal voltage for the working chiller! As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 200 250V 110V model. If you do need a wider operating voltage range, customization is available for us. To protect the pump, its strictly forbidden to run the chiller without having water in the storage water tank!

The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise its easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly.

Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited! Please be sure that the air inlet and air outlet are in good ventilation!

There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet. The filter screen must be regularly cleaned!

Its essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller. Please pay attention to the effect of the condensate water! With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm.

CW-5200 industrial water chiller cool for a single 8KW spindle. CW5200 water chiller cool for 2 x 100W laser tube. Mounted on the power socket. Cooling water additive is forbidden by express company, so we could not put it into the package.

The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction, children supervised not to play with the appliance! The item "US S&A CW-5200DH Industrial Water Chiller 110V 60Hz for 8KW Spindle Laser Tube" is in sale since Wednesday, September 4, 2019. This item is in the category "Business & Industrial\Healthcare, Lab & Dental\Medical & Lab Equipment, Devices\Water Baths, Circulators & Chillers". The seller is "colorfulworldprinting" and is located in Chino, California.

This item can be shipped worldwide.
US S&A CW-5200DH Industrial Water Chiller 110V 60Hz for 8KW Spindle Laser Tube


Index  Archives  Contact Form  Privacy Policies  Terms of Use